FN Archimer Export Format PT J TI Spectrophotometric Winkler determination of dissolved oxygen: re-examination of critical factors and reliability BT AF LABASQUE, Thierry CHAUMERY, Christian AMINOT, Alain KERGOAT, Gilles AS 1:;2:;3:;4:; FF 1:;2:;3:PDG-DEL-EC-EB;4:; C1 Serv Hydrog & Oceanog Marine, Etab Principal, F-29603 Brest, France. Inst Univ Europeen Mer, Lab Chim Marine, F-29280 Plouzane, France. IFREMER, Ctr Brest, Direct Environm & Amenagement Littoral, Dept Ecol Cotiere, F-29280 Plouzane, France. C2 SERV HYDROG & OCEANOG MARINE, FRANCE UNIV BRETAGNE OCCIDENTALE, FRANCE IFREMER, FRANCE SI BREST SE PDG-DEL-EC-EB IN WOS Ifremer jusqu'en 2018 copubli-univ-france IF 2.508 TC 87 UR https://archimer.ifremer.fr/doc/2004/publication-1694.pdf LA English DT Article DE ;Isobestic point;Sea water;Spectrophotometry;Dissolved oxygen AB The spectrophotometric iodine measurement for oxygen determination by the Winkler method is re-examined for theoretical and operational aspects. It is shown that the selection of an isobestic point for measuring the mixture of iodine and tri-iodide in the solution enhances reliability. The wavelength value of 466 nm was selected after a spectrum study. Then, performances are assessed by mean of statistical approach based on repeated standardization curves at the isobestic point compared with other wavelengths. At 466 nm, the method is linear up to about 1000 mumol kg(-1) of O-2. Optimization and validation of the spectrophotometric method is realized through a robustness study based on factors that may alter the results (temperature, reagent volumes, storage time). Temperature is the only factor that exerts a significant influence on the absorbance (0.5% per degreesC), hence samples and standards should be kept at the same temperature within +/-1 degreesC. Precision was estimated over a 10-day period. The standard deviation was 0.45% for inter-sample repeatability and 0.73% for reproducibility near 250 mumol kg(-1). The repeatability of 12 samples taken at the same immersion was around 0.12%. The detection limit, determined from standardization curves, is <2 mumol kg(-1). Accuracy was verified with O-2 saturated seawater and found to be within the precision confidence interval. The method can be applied to the determination of dissolved oxygen in fresh or seawater samples, suboxic, or waters supersaturated in dissolved oxygen. It is suggested as being a suitable alternative to titration in most applications of the Winkler determination of dissolved oxygen. (C) 2004 Elsevier B.V. All rights reserved. PY 2004 PD AUG SO Marine Chemistry SN 0304-4203 PU Elsevier VL 88 IS 1-2 UT 000221915000004 BP 53 EP 60 DI 10.1016/j.marchem.2004.03.004 ID 1694 ER EF