FN Archimer Export Format PT J TI Evaluation of removal of noroviruses during wastewater treatment, using real-time reverse transcription-PCR: Different behaviors of genogroups I and II BT AF DA SILVA, A LE SAUX, Jean-Claude PARNAUDEAU, Sylvain POMMEPUY, Monique ELIMELECH, M LE GUYADER, Soizick AS 1:2;2:1;3:1;4:1;5:2;6:1; FF 1:;2:PDG-DOP-DCN-EMP-MIC;3:PDG-DOP-DCN-EMP-MIC;4:PDG-DOP-DCN-EMP;5:;6:PDG-DOP-DCN-EMP-MIC; C1 Microbiol Lab, IFREMER, F-44311 Nantes, France. Yale Univ, Dept Chem Engn, Environm Engn Program, New Haven, CT 06520 USA. C2 IFREMER, FRANCE UNIV YALE, USA SI BREST NANTES SE PDG-DOP-DCN-EMP-MIC PDG-DOP-DCN-EMP IN WOS Ifremer jusqu'en 2018 copubli-int-hors-europe IF 4.004 TC 377 UR https://archimer.ifremer.fr/doc/2007/publication-3571.pdf LA English DT Article AB Noroviruses, an important cause of gastroenteritis, are excreted by infected individuals and are therefore present in wastewater. We quantified norovirus genogroup I (GI) and GII in wastewater at different locations in France and evaluated removal by a range of treatment types, including basic (waste stabilization pond), current industry standard (activated sludge), and state-of-the-art (submerged membrane bioreactor) treatments. Noroviruses were quantified using real-time reverse transcription-PCR (rRT-PCR). Mengovirus was used as a virus extraction control, and internal controls were used to verify the level of GI and GII rRT-PCR inhibition. A total of 161 (81 influent and 79 effluent) samples were examined; GI and GII were detected in 43 and 88% of the influent samples, respectively, and in 24 and 14% of the effluent samples, respectively. Physicians in France report far more cases of GII than GI during outbreaks; thus, the frequent presence of GI was unexpected. The GI influent concentrations were more variable, the peak GI influent concentrations were higher than the peak GII influent concentrations at all four sites (up to 1 x 10(9) and 6 x 10(7) genome copies/liter, respectively), and the average positive influent concentrations of GI were higher than the average positive influent concentrations of GII The maximum effluent breakthrough concentrations were 6 x 10(6) and 3 x 10(6) genome copies/liter for GI and GII, respectively, indicating that the four treatment systems studied decreased the norovirus contamination load in receiving waters. PY 2007 PD DEC SO Applied and environmental microbiology SN 0099-2240 PU American society for microbiology VL 73 IS 24 UT 000251902300012 BP 7891 EP 7897 DI 10.1128/AEM.01428-07 ID 3571 ER EF