FN Archimer Export Format PT J TI Measuring production-dissolution rates of marine biogenic silica by Si-30-isotope dilution using a high-resolution sector field inductively coupled plasma mass spectrometer BT AF FRIPIAT, Francois CORVAISIER, Rudolph NAVEZ, Jacques ELSKENS, Marc SCHOEMANN, Veronique LEBLANC, Karine ANDRE, Luc CARDINAL, Damien AS 1:1,2;2:3;3:1;4:4;5:5;6:6,7;7:1;8:1; FF 1:;2:;3:;4:;5:;6:;7:;8:; C1 Royal Museum Cent Afr, Sect Mineral & Petrog, Tervuren, Belgium. Univ Libre Brussels, Dept Earth & Environm Sci, Brussels, Belgium. Univ Bretagne Occidentale, Inst Univ Europeen Mer, CNRS, LEMAR Lab Sci Environm Marin,UMR 6539, Plouzane, France. Vrije Univ Brussel, Brussels, Belgium. Ecologie des Systèmes Aquatiques, Université Libre de Bruxelles, Campus de la Plaine, CP221, Brussels, Belgium Univ Aix Marseille, CNRS, UMR 6535, LOPB,OSU Ctr Oceanol Marseille, Marseille, France. CNRS, UMR 6535, INSU, Marseille, France. C2 RMCA, BELGIUM UNIV LIBRE BRUXELLES, BELGIUM UBO, FRANCE UNIV VRIJE BRUSSEL, BELGIUM UNIV LIBRE BRUXELLES, BELGIUM UNIV AIX MARSEILLE, FRANCE CNRS, FRANCE IF 1.737 TC 8 UR https://archimer.ifremer.fr/doc/00205/31607/30033.pdf LA English DT Article CR MD 145 / KEOPS BO Marion Dufresne DE ;isotopic fractionation;southern ocean;acid uptake;waters;phytoplankton;environments;biosilica;recovery;balance;tracer AB Regional and seasonal variability of the Si dissolution: production ratios in the surface ocean have not been well assessed. Here, we propose a new method for determining these rates, using the Si-30-isotopic dilution technique with a high-resolution sector field inductively coupled plasma mass spectrometer (HR-SF-ICP-MS). Relative analytical precision of the isotopic measurement is better than 1%, similar to that obtained by thermal ionization-quadrupole mass spectrometry (TIMS). Accuracy and reproducibility of the isotopic measurements have been checked on artificial and natural solutions by intercomparison between two HR-SF-ICP-MS instruments and one TIMS. Measurements of real Si production and dissolution rates are illustrated for two contrasted situations with an average relative precision of 10%, including one from waters with low Si content (2 mu mol L-1), which required an additional purification step by cation exchange chromatography. Si production rate from this later incubation was not significantly different from the one measured by radioactive Si-32. The new method is faster and simpler than TIMS or isotope ratio mass spectrometry (IRMS). Its sensitivity is more than one order of magnitude better than TIMS, and it can cover the whole range of Si concentrations encountered in the ocean. PY 2009 PD JUN SO Limnology And Oceanography-methods SN 1541-5856 PU Amer Soc Limnology Oceanography VL 7 UT 000268838700001 BP 470 EP 478 ID 31607 ER EF